Test standard: TL 82002, 2018-05, 6.5 & 6.7
Test standard: VW80000, 2017-10, 10.7
Use medium: 1:1 mixture of ethylene glycol and water (Precise ratio according to the type of coolant specified by the manufacturer, such as BSF G40)
Test piece: cooling flow channel of new energy vehicle battery system (Liquid flow water cooling plate)
Maximum size of the test piece: 2400mm X 1700mm X 400mm (Cooling flow path inside the sample)
Maximum number of test piece tested at the same time: 1-3 (Or more)
Cooling runner volume inside the test piece:<5L
Walk-in environment box: RT-110°C
Medium temperature: RT-110 °C