A. Pressure range: 0.5~100 Bar, according to the set pressure choose relevant pressure sensor to improve pressure control feedback and measurement accuracy.
B. Test medium: Water (H₂O)
C. Medium temperature: 20±5℃, automatic control constant temperature
D. Safety observation door: Observation window with 17mm bulletproof glass, with lighting system
E. Test items:
Burst test: Direct burst
Holding pressure burst: Boost-hold pressure-burst, pressure, pressure holding time can be set arbitrarily
Multi-step pressure holding test: Boost→hold pressure→boost→hold pressure→boost→hold pressure→boost→hold pressure→boost→hold pressure→burst five steps boost and hold pressure, pressure, time can be set, number of the steps is optional
Fatigue test: boost → hold pressure → pressure relief, low frequency cycle
Total boost rate: 3~30KPa/s can be adjusted